Profibus DP Operating instructions
SideStep
®
Industrial Positioner
7/43
7. Cyclic Profibus data
Input data: (Profibus Å SideStep)
Addr. 0 Addr. 2 Addr. 3
2
bytes
1
byte
8 bytes
Position
Dig.
Out
Parameters / Actions / Errors
Output data: (Profibus Æ SideStep)
Addr. 0 Addr. 2 Addr. 4 Addr. 5
2
bytes
2
bytes
1
byte
8 bytes
Set value Actual value Dig. In Parameters / Action / Errors
7.1. Set value
Profibus Æ SideStep
The set value is transmitted from the master to the SideStep in per mille.
Excessive set values (0x11) trigger an external diagnostic error.
0..1000
2 bytes
7.2. Actual value
Profibus Æ SideStep
The actual value is transmitted from the master to the SideStep in per mille.
Excessive actual values (0x13) trigger an external diagnostic error.
0..1000
2 bytes